TEST DIRECTORY

0 selected

Laboratory:Akiruno

GATA2-MECOM inv(3) inversion,t(3;3) translocation

  • TEST NAME SPECIMEN
    REQUIREMENT
    (mL)
    CONTAINER CAP COLOR STORE
    TEMPERATURE
    (STABILITY)
    TURNAROUND
    TIME (DAY)
    METHODOLOGY REFERENCE RANGE
    (UNIT)
  • Specified days
    GATA2-MECOM inv(3) inversion,t(3;3) translocation
    bone marrow aspirate
    1.0
    H00 Refrigeration
    7-10 FISH

    (Various) Band
    Culture lymphocytes or bone marrow cells, and fix metaphase cells. This method then stains the chromosomes with a dye to create a striped pattern (band), and analyzes the distribution and density of the band.
    G-Banding, which performs Giemsa staining after treatment with trypsin solution, C-Banding, which performs Giemsa staining after treatment with HCI, Ba (OH) 2, 2×SCC, these include Q-Banding, which involves staining with quinacrine mustard and then observing with a fluorescence microscope, and high-precision banding, which uses mitotic images from the end of prophase to the beginning of metaphase, and observes a larger number of bands than usual.

other material

COMMENT


Avoid freezing. Acceptable days are Monday through Friday.
About Submission of Chromosome Testing Submit the specimen on the same day after collection.
Collect 1.0 mL of bone marrow fluid aseptically in the container shown below, mix well, and preserve refrigerated. Please submit on the same day.

CONTAINER

supplementary information

Notifications of URL changes/lab information added

ラボを選択してください

Choose a laboratory

Notifications of URL changes/lab information added

Laboratory List