GATA2-MECOM inv(3) inversion,t(3;3) translocation

  • TEST NAME SPECIMEN
    REQUIREMENT
    (mL)
    CONTAINER CAP COLOR STORE
    TEMPERATURE
    (STABILITY)
    TURNAROUND
    TIME (DAY)
    METHODOLOGY REFERENCE RANGE
    (UNIT)
  • Specified days
    GATA2-MECOM inv(3) inversion,t(3;3) translocation
    Blood (heparin added)
    5.0
    PH5 Refrigeration
    7-10 FISH

    FISH (Fluorescence in situ hybridization)
    Fluorescence in situ hybridization
    Hybridizes with the target DNA using a probe labeled with a fluorescent dye, and uses the fluorescent site that develops at a specific wavelength as a signal on the chromosome. How to detect under fluorescence microscope.
    There is a direct method in which a probe labeled with a fluorescent dye is directly bound to the target DNA, and an indirect method in which the probe labeled with a labeling substance is bound to the target DNA, and then the labeled probe and fluorescent substance are bound to develop color. .

other material

COMMENT


Avoid freezing. Acceptable days are Monday to Friday.
About submitting a chromosome test Please submit the specimen on the same day after it is collected.
Collect blood into the container shown below, mix well, and store in the refrigerator. Please submit the specimen on the same day after collection.