Laboratory:Akiruno

Laboratory:Akiruno
CODE:06208 4(旧 6208 7)
FISH (Fluorescence in situ hybridization)
Fluorescence in situ hybridization
Hybridizes with the target DNA using a probe labeled with a fluorescent dye, and uses the fluorescent site that develops at a specific wavelength as a signal on the chromosome. How to detect under fluorescence microscope.
There is a direct method in which a probe labeled with a fluorescent dye is directly bound to the target DNA, and an indirect method in which the probe labeled with a labeling substance is bound to the target DNA, and then the labeled probe and fluorescent substance are bound to develop color.
Avoid freezing. Acceptable days are Monday through Friday.
-About Submission of Chromosome Testing
Submit the specimen on the same day after collection.
Collect blood in the container shown below, mix well, and preserve refrigerated.

ヘパリン入り (真空採血量5mL)
内容:ヘパリンNa 65IU
貯蔵方法:室温
有効期間:製造から2年