TEST DIRECTORY

0 selected

Laboratory:Akiruno

MINtS lung cancer multi-3CDx
(Reference information available)

  • TEST NAME SPECIMEN
    REQUIREMENT
    (mL)
    CONTAINER CAP COLOR STORE
    TEMPERATURE
    (STABILITY)
    TURNAROUND
    TIME (DAY)
    METHODOLOGY REFERENCE RANGE
    (UNIT)
  • MINtS lung cancer multi-3CDx
    (Reference information available)
    Unstained specimen slide
    and
    HE stained slide

    10 sheets, thickness 5μm
    and
    1 sheet
    Z10 Refrigeration
    13-20 Next Generation Sequencing (NGS)

    A method that uses a next-generation sequencer to simultaneously determine the base sequences of a huge number of DNA fragments.

TEST NAME

SPECIMEN
REQUIREMENT
(mL)

CONTAINER

MINtS lung cancer multi-3CDx
(Reference information available)

Unstained specimen slide
and
HE stained slide

10 sheets, thickness 5μm
and
1 sheet

CAP COLOR

STORE
TEMPERATURE
(STABILITY)

TURNAROUND
TIME (DAY)

Refrigeration

13-20

METHODOLOGY

REFERENCE RANGE
(UNIT)

Next Generation Sequencing (NGS)

A method that uses a next-generation sequencer to simultaneously determine the base sequences of a huge number of DNA fragments.

COMMENT


The purpose of this test is to detectEGFR gene mutations, ALK fusion genes, and BRAF gene V600E mutations using nucleic acids extracted from cancer tissue, and to determine the suitability of drugs for non-small cell lung cancer. We will also report the analysis results, which have not been approved by pharmaceutical regulations, for research purposes only.
The recommended percentage of tumor cells required for testing is 10% or more.
When submitting samples, please follow the detailed sample submission information provided in the ”Cytology Sample Collection and Processing Operation Manual” issued by EIKEN CHEMICAL CO.,LTD.
Please see below for points to note when submitting unstained specimen slides. When submitting unstained specimen slides, please be sure to also submit one HE-stained specimen with the tumor cell area marked.
Please avoid cryopreservation.
Please avoid requests that overlap with other items. This testing method is more susceptible to contamination, so please be careful when handling samples.
●When requesting this test
Please submit the sample according to the sample submission method described in the following document issued by EIKEN CHEMICAL CO.,LTD. for each test material. https://mints.eiken.co.jp/
-Cytological sample collection and processing operation manual
-Quality of cytological samples (guideline for total nucleic acid yield and sample appearance)
-How to submit bronchoscope cytodiagnosis samples
-How to submit pleural effusion samples for carcinomatous pleurisy
-How to submit FFPE samples

CONTAINER

[Object cases] Preparation (slide glass)

Z10  Previous container symbol t

[Object cases] Preparation (slide glass)

Storage method: Room temperature

supplementary information

Drugs related to target gene mutations and applicable cancers

Gene Mutations, etc. Cancer Related Drugs
EGFR gene mutation non-small cell lung cancer Gefitinib, Erlotinib hydrochloride, Afatinib maleate, Osimertinib mesylate, Dacomitinib hydrate
ALK fusion gene Alectinib Hydrochloride, Crizotinib, Brigatinib, Ceritinib, Lorlatinib
BRAF gene (V600E mutation) Coadministration of Dabrafenib mesilate and Trametinib dimethyl sulfoxide

Notifications of URL changes/lab information added

ラボを選択してください

Choose a laboratory

Notifications of URL changes/lab information added

Laboratory List