Laboratory:Akiruno

Laboratory:Akiruno
CODE:08845 5
ELISA (Enzyme-Linked immunosorbent assay)
Enzyme-linked immunosorbent assay
After reacting the antigen with the immobilized antibody, the enzyme-labeled antibody is reacted with the antigen secondarily, and a chromogenic substrate is added. A method of measuring enzyme activity.
TEST NAME | SPECIMEN | CONTAINER |
---|---|---|
IL-8 (interleukin-8)
|
Plasma
|
CAP COLOR | STORE | TURNAROUND |
---|---|---|
| Please contact us in advance. |
METHODOLOGY | REFERENCE RANGE |
---|---|
ELISA ELISA (Enzyme-Linked immunosorbent assay) | 2.0 or less (Reference value)(pg/mL) |
Serum samples will have high values.
Collect blood into the specified container, mix well, and separate the plasma. Be sure to store plasma frozen.
With EDTA-2Na (2mL vacuum blood sampling tube)
Contents: EDTA-2Na 3.0 mg
Storage method: Room temperature
Expiration period: 2 years from production
With EDTA-2Na (5mL vacuum blood sampling tube)
Contents: EDTA-2Na 7.5 mg
Storage method: Room temperature
Expiration period: 2 years from production
Polyethylene test tube
Storage method: Room temperature