TEST DIRECTORY

0 selected

Laboratory:Akiruno

Chlamydophila (Chlamydia psittaci)

  • TEST NAME SPECIMEN
    REQUIREMENT
    (mL)
    CONTAINER CAP COLOR STORE
    TEMPERATURE
    (STABILITY)
    TURNAROUND
    TIME (DAY)
    METHODOLOGY REFERENCE RANGE
    (UNIT)
  • Chlamydophila (Chlamydia psittaci)
    Immediately
    Serum
    0.3
    S09

    A00
    Refrigeration
    4-6 CF (complement fixation reaction)

    CF (Complement fixation)
    Complement fixation reaction
    A method that utilizes the fact that complement binds to antigen-antibody complexes and causes a hemolytic reaction.
    Sensitized red blood cells with hemolysin bound to red blood cells cause hemolysis when complement binds to them, but if antigen-antibody complexes are present, complement is consumed and hemolysis is prevented. Determine existence.

    Less than 4(X)

TEST NAME

SPECIMEN
REQUIREMENT
(mL)

CONTAINER

Chlamydophila (Chlamydia psittaci)

Immediately
Serum
0.3

CAP COLOR

STORE
TEMPERATURE
(STABILITY)

TURNAROUND
TIME (DAY)

Refrigeration

4-6

METHODOLOGY

REFERENCE RANGE
(UNIT)

CF (complement fixation reaction)

CF (Complement fixation)
Complement fixation reaction
A method that utilizes the fact that complement binds to antigen-antibody complexes and causes a hemolytic reaction.
Sensitized red blood cells with hemolysin bound to red blood cells cause hemolysis when complement binds to them, but if antigen-antibody complexes are present, complement is consumed and hemolysis is prevented. Determine existence.

Less than 4(X)

COMMENT


See below (*CF)
*CF (Complement fixation reaction): An anti-complement effect is observed in the complement fixation reaction, which may make measurements impossible, so please collect the blood without adding anticoagulant, separate the serum immediately, and store it in the refrigerator.
Starting dilution 4x (Cerebrospinal fluid can also be measured; sample volume: 0.4mL (refrigerated), standard value: less than 1x, starting dilution: 1x)

CONTAINER

With separating agent (9mL vacuum blood sampling tube)

S09

With separating agent (9mL vacuum blood sampling tube)

Storage method: Room temperature
Expiration period: 1 year from production

Polyethylene test tube

A00  Previous container symbol X

Polyethylene test tube

Storage method: Room temperature

supplementary information