Laboratory:Akiruno
- TOP
- viral infection test
- viral infection test
- Japanese encephalitis virus
Laboratory:Akiruno
○Japanese encephalitis virus
CODE:06964 5
-
TEST NAME
SPECIMEN
REQUIREMENT
(mL) CONTAINER CAP COLOR STORE
TEMPERATURE
(STABILITY) TURNAROUND
TIME (DAY) METHODOLOGY REFERENCE RANGE
(UNIT) -
Japanese encephalitis virus
Serum
0.3
S09
↓
A00
4-6 CF (complement fixation reaction)Less than 4(X)CF (Complement fixation)
Complement fixation reaction
A method that utilizes the fact that complement binds to antigen-antibody complexes and causes a hemolytic reaction.
Sensitized red blood cells with hemolysin bound to red blood cells cause hemolysis when complement binds to them, but if antigen-antibody complexes are present, complement is consumed and hemolysis is prevented. Determine existence.
COMMENT
See below (*CF)
*CF (Complement fixation reaction): An anti-complement effect is observed in the complement fixation reaction, which may make measurements impossible, so please collect the blood without adding anticoagulant, separate the serum immediately, and store it in the refrigerator.
Starting dilution 4x (Cerebrospinal fluid can also be measured; sample volume: 0.4mL (refrigerated), standard value: less than 1x, starting dilution: 1x)
CONTAINER
S09 旧容器記号 C1 1 セ X1
分離剤入り (真空採血量9mL)
貯蔵方法:室温
有効期間:製造から1年
A00 旧容器記号 X
ポリスピッツ
貯蔵方法:室温