Laboratory:Akiruno
- TOP
- serum immunological test
- infections disease (non virus) related test
- Endotoxin quantitative
Laboratory:Akiruno
○Endotoxin quantitative
CODE:06595 5
-
TEST NAME
SPECIMEN
REQUIREMENT
(mL) CONTAINER CAP COLOR STORE
TEMPERATURE
(STABILITY) TURNAROUND
TIME (DAY) METHODOLOGY REFERENCE RANGE
(UNIT) -
Endotoxin quantitative
Blood (Novo-Heparin added)
2.0
PE2
2-4 Nephelometric analysis method 1.0 or less (cutoff value) (pg/mL)
COMMENT
Avoid freezing. The cutoff value is 1.0 pg/mL for the diagnosis of sepsis due to Gram-negative bacteria. Those of 1.1 pg/mL or higher is suspected of sepsis caused by Gram-negative bacteria. Please avoid duplicate requests of items other than β-D-glucan. In this test, endotoxin in plasma is measured. Collect 2.0 mL of blood in a special container (PE2) and mix well. Please submit the data immediately under refrigeration as the data will be affected.
Collect blood in the container shown in the figure below and mix well. Please submit the data immediately under refrigeration as the data will be affected if preserved at room temperature.
Please avoid duplicate requests of items other than β-D-glucan.
CONTAINER
PE2 旧容器記号 T3 22
(真空採血量2mL)
内容:ノボヘパリン 15IU
貯蔵方法:室温
有効期間:製造から1年