Detectable types are 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, and 68 types. For this test, please submit samples collected from a patient who has been histologically diagnosed with CIN1 or CIN2 in a special container V41. This testing method can be affected by contamination, so please be careful when collecting and handling the specimen. Please avoid duplicate requests with other items. [02326 7] Cytology (gynecology LBC) or [06241 7] cytology (gynecology LBC Bethesda System) can be requested only at the same time, but in that case, the required time for cytology will be delayed by 1-2 days.
CONTAINER
2024/04/10→大原
2019/01/29
未確認
未確認
未確認
未確認
未確認
未確認
未確認
未確認
未確認
未確認
未確認
2020/11/20
2024/04/10
V41
旧容器記号 f6
内容:メタノール55%
貯蔵方法:室温
有効期間:製造から1年6ヵ月
V41
Previous container symbol
f6
Contents: Methanol 55%
Storage method: Room temperature
Expiration period: 1 year and 6 months from production
V41 (Previous container symbol f6) Specimen handling method
Collection method
Collect cells from the cervix.
Collect cells using a collection equipment other than a cotton swab
(brush, spatula, etc.).
Wash off the cells.
Place the collection equipment in the container and press the tip
of the collection equipment against the bottom of the container about 10 times
so that the tip spreads, then stir vigorously to wash off the collected cells.
Close the lid tightly.
Remove the collection equipment and close the lid tightly so that the black line
on the lid extends to the left beyond the black line on the container body,
then store it.
(Note) Do not leave the tip of the collection equipment in the container.
[Notes]
When collecting cells from a pregnant woman, for safety reasons,
please avoid using collection equipment such as brushes
and spatulas and use cotton swabs instead.
However, in order to collect the amount of cells needed for testing with a cotton swab,
remove any mucus with a separate cotton swab before collection,
and then rinse the cotton swab thoroughly in preservative solution
to wash off the collected cells.
Do not leave the tip of the cotton swab in the container. In addition,
be careful not to apply excessive force to the cotton swab as it may break.
Notifications of URL changes/lab information added
You can now view test items from all labs.
Please choose a lab from the list below.
You can switch between labs as any time using the upper right lab icon.
The domain name of the TEST DIRECTORYpage has changed.
Please update bookmarks and saved links with the new address.
Notifications of URL changes/lab information added
You can now view test items from all labs.
Please choose a lab from the list below.
You can switch between labs as any time using the upper right lab icon.
The domain name of the TEST DIRECTORYpage has changed.
Please update bookmarks and saved links with the new address.