Laboratory:Akiruno

Laboratory:Akiruno
CODE:06405 5
Enzyme-antibody method
A method in which an antigen-antibody reaction is performed against the target antigen using an enzyme-labeled antibody, and a chromogenic substrate is added to measure the enzyme activity.
There are two methods: a direct method in which an enzyme-labeled antibody reacts directly with the antigen, and an indirect method in which an unlabeled antibody reacts with the antigen followed by a secondary reaction with an enzyme-labeled antibody.
Slice the tissue to a thickness of 3 to 4 μm, and paste it as close to the center as possible, at least 15 mm from the edge of the frost and at least 15 mm from the edge of the slide glass. Please use a slide to coat with silane, etc., and after slicing, dry at approximately 40℃ overnight before submitting.
[オブジェクトケース]
プレパラート (スライドグラス)
貯蔵方法:室温