TEST DIRECTORY

0 selected

Laboratory:Akiruno

Human chorionic gonadotropin (HCG)

  • TEST NAME SPECIMEN
    REQUIREMENT
    (mL)
    CONTAINER CAP COLOR STORE
    TEMPERATURE
    (STABILITY)
    TURNAROUND
    TIME (DAY)
    METHODOLOGY REFERENCE RANGE
    (UNIT)
  • Human chorionic gonadotropin (HCG)
    Serum
    0.5
    S09

    A00
    Refrigeration
    2-4 CLEIA

    CLEIA (Chemiluminescent enzyme immunoassay)
    A method in which an antigen is reacted with a solid-phase antibody, an enzyme-labeled antibody is reacted with the antigen in a secondary reaction, a chemiluminescent substrate is added and the luminescence intensity is measured.

    2.7以下(mIU/mL)

COMMENT


Total HCG is measured. The antibody recognizes HCG-β. It is useful for the diagnosis and prognosis management of trophoblastic diseases. This is the recommended method in “Terms of Management for Trophoblastic Disorders, 3rd Edition”, and the measurement sensitivity is 1.0 mIU/mL.

CONTAINER

Notifications of URL changes/lab information added

ラボを選択してください

Choose a laboratory

Notifications of URL changes/lab information added