Laboratory:Akiruno
- TOP
- gene-related test
- genetic tests for hematopoietic tumor
- FLT3 mutation analysis ITD/TKD
Laboratory:Akiruno
○FLT3 mutation analysis ITD/TKD
CODE:02875 8
-
TEST NAME
SPECIMEN
REQUIREMENT
(mL) CONTAINER CAP COLOR STORE
TEMPERATURE
(STABILITY) TURNAROUND
TIME (DAY) METHODOLOGY REFERENCE RANGE
(UNIT) -
FLT3 mutation analysis ITD/TKD
bone marrow aspirate
1.0
H00
(7 days)
4-8 PCR-capillary electrophoresis method Negative
other material
COMMENT
Avoid freezing. Please avoid duplicate requests with other items. This testing method increases the effects of contamination, so please be careful when handling the specimen.
This test can also be submitted using a blood collection tube containing EDTA-2Na (PN5).
About submission of hematopoietic tumor genetic testing
Please submit the specimen on the same day after collection.
Collect 1.0 mL of bone marrow fluid aseptically into the container shown below, mix well, and store refrigerated.
After collecting the specimen, please submit it on the same day.
CONTAINER
H00 旧容器記号 H
保存液入り (容器容量5mL)
内容:RPMI-1640 FBS 硫酸カナマイシン ノボヘパリンNa 炭酸水素Na HEPES
貯蔵方法:凍結
有効期間:色が薄いピンクの状態で使用してください。
(凍結時は淡黄色ですが解凍すると薄いピンク色に戻ります。)
supplementary information
FLT3変異解析ITD/TKDの判定基準
FLT3変異解析 | ITD SIGNAL RATIO | ||
---|---|---|---|
0.05未満 | 0.05以上 | ||
TKD SIGNAL RATIO | 0.05未満 | 陰性 | 陽性 |
0.05以上 | 陽性 | 陽性 |