TEST DIRECTORY

0 selected

Laboratory:Akiruno

Flecainide

  • TEST NAME SPECIMEN
    REQUIREMENT
    (mL)
    CONTAINER CAP COLOR STORE
    TEMPERATURE
    (STABILITY)
    TURNAROUND
    TIME (DAY)
    METHODOLOGY REFERENCE RANGE
    (UNIT)
    BLOOD COLLECTION TIME
  • Flecainide
    Serum
    0.3
    S7P

    A00
    Refrigeration
    3-5 LC/MS/MS

    LC/MS/MS (Liquid chromatography tandem mass spectrometry)
    Liquid chromatography tandem quadrupole mass spectrometry
    A method in which the components of a substance of interest are resolved using affinity differences in a liquid chromatograph, further separated by mass in a mass spectrometer to dissociate and fragment specific mass ions, and those ions are then detected.

    200-1000(ng/mL) Immediately before next administration (Trough concentration)
other material

COMMENT


Tambocor
Precautions regarding blood collection containers 
Avoid using containers containing serum separating agents. It may affect the measured values in drug tests.
Notes on blood sampling time
1. Blood sampling time for TDM (blood drug concentration monitor).
2. For continuous administration, collect blood after reaching a steady state.
3. Peak concentration must also be measured at the time of poisoning.
4. This is a standard time, and it is preferable to draw blood according to the patient's situation.

CONTAINER

Notifications of URL changes/lab information added

ラボを選択してください

Choose a laboratory

Notifications of URL changes/lab information added

Laboratory List