Laboratory:Akiruno

Laboratory:Akiruno
CODE:06144 5(旧 0U99 2)
CLEIA (Chemiluminescent enzyme immunoassay)
A method in which an antigen is reacted with a solid-phase antibody, an enzyme-labeled antibody is reacted with the antigen in a secondary reaction, a chemiluminescent substrate is added and the luminescence intensity is measured.
Total HCG is measured. The antibody recognizes HCG-β. It is useful for the diagnosis and prognosis management of trophoblastic diseases. This is the recommended method in “Terms of Management for Trophoblastic Disorders, 3rd Edition”, and the measurement sensitivity is 1.0 mIU/mL.

分離剤+凝固促進フィルム入り (真空採血量9mL)
貯蔵方法:室温
有効期間:製造から1年

ポリスピッツ
貯蔵方法:室温