TEST DIRECTORY

0 selected

Laboratory:Akiruno

Estrogen receptor (IHC)

  • TEST NAME SPECIMEN SUBMISSION SPECIMEN
    REQUIREMENT
    CONTAINER CAP COLOR STORE
    TEMPERATURE
    (STABILITY)
    TURNAROUND
    TIME (DAY)
    METHODOLOGY
  • Estrogen receptor (IHC)
    Unstained specimen slide 4 unstained slide specimens Z10 Room temperature
    7-9 Immunohistochemical staining method

TEST NAME

SPECIMEN SUBMISSION

SPECIMEN
REQUIREMENT

Estrogen receptor (IHC)

Unstained specimen slide

4 unstained slide specimens

CONTAINER

CAP COLOR

STORE
TEMPERATURE
(STABILITY)

Room temperature

TURNAROUND
TIME (DAY)

METHODOLOGY

7-9

Immunohistochemical staining method

CONTAINER

[Object cases] Preparation (slide glass)

Z10  Previous container symbol t

[Object cases] Preparation (slide glass)

Storage method: Room temperature

supplementary information

Submission method

  • This test is to determine the treatment policy for cases for which a definitive diagnosis has been made by pathological test, so please fill in the pathological diagnosis name and tissue type on the pathological test request form before requesting.
  • Since the presence or absence of cancer cells and the tissue type may be unknown, please attach a copy of the pathology report at the time of the test request. (However, this is not necessary if a general pathology test has been performed at our company.)
    If you are unable to attach the pathology report due to various reasons, please provide the name of the pathology diagnosis (tissue type, etc.) and as much clinical information as possible on the pathology test request form.
  • The material should be unstained specimen slides (made from formalin-fixed paraffin blocks) of breast cancer (primary or metastatic). Please use silane or other coating slides, and after thinning, please dry the slides overnight at approximately 40°C before submitting them.
    The recommended fixation time is as follows in 10% neutral buffered formalin.
    【Fixation time】
    Item code Test item Time
    00A08 2 Estrogen receptor (IHC) 6-48 hours
    00A12 7 Progesterone receptor (IHC) 6-48 hours
    00A16 3 Estrogen receptor/progesterone receptor (IHC) 6-48 hours
    00A28 0 Breast cancer HER2 gene (FISH) 24-48 hours
  • If you request immunohistochemical staining, please thin slice the tissue sections to a thickness of 4 µm.
    If FISH is requested, thin slice the tissue sections to a thickness of 4-6 µm.
    Tissue sections should be affixed in the center as much as possible.
  • If you have already performed IHC or FISH test for breast cancer HER2, please indicate the test results on the request form.