Laboratory:Akiruno

Laboratory:Akiruno
CODE:00555 5
EIA (Enzyme immunoassay)
Enzyme immunoassay
The measurement principle is the same as RIA; an antigen-antibody reaction is performed using an enzyme-labeled antigen or antibody as a labeling substance, and a chromogenic substrate is added to detect enzyme activity. How to measure.
TEST NAME | SPECIMEN | CONTAINER |
---|---|---|
Platelet factor-4 (PF-4)
|
|
CAP COLOR | STORE | TURNAROUND |
---|---|---|
| 2-9 |
METHODOLOGY | REFERENCE RANGE |
---|---|
Enzyme immunoassay(EIA) EIA (Enzyme immunoassay) | 20 or less (ng/mL) |
Please see below for sampling method.
(Do not use a vacuum tube.)
With antiplatelet agent
Contents: Theophylline Adenosine Dipyridamole Sodium citrate Citric acid
Storage method: Refrigeration and protection from light
Expiration period: 1 year from production
Polyethylene test tube
Storage method: Room temperature
Points to note
Make sure that the surface of specimen in the dedicated container is below the surface of the ice water.
Do not use ice cubes.
Points to note
Do not use any vacuum blood sampling tube, catheter, or other sampling methods.
Also, do not use any tourniquets.Avoid drawing ≥10 mL of blood.Collect blood smoothly while avoiding any damage to the vascular walls.
Points to note
Use only the dedicated container. Do not shake the dedicated container.
Points to note
Make sure that the surface of blood in the dedicated container is below the surface of the ice water.
Proceed to the following procedures within 2 minutes.
* Equation of the rotating speed of the centrifuge
G=1.118×10-5×r×n2
r:radius of the centrifuge rotor (cm)
n:number of revolutions per minute (rpm)
Points to note
Make sure to centrifuge within 1 hour under cool conditions.
Make sure to centrifuge within 1 hour under cool conditions.
Radius (cm) | Speed (rpm) |
---|---|
10 | 4200 |
12 | 3800 |
14 | 3500 |
16 | 3300 |
18 | 3100 |
20 | 3000 |
Radius (cm) | Speed (rpm) |
---|---|
22 | 2800 |
24 | 2700 |
26 | 2600 |
28 | 2500 |
30 | 2400 |