Laboratory:Akiruno
○Irregular antibodies (antibody identification/antibody titer measurement)
CODE:00347 6
-
TEST NAME
SPECIMEN
REQUIREMENT
(mL) CONTAINER CAP COLOR STORE
TEMPERATURE
(STABILITY) TURNAROUND
TIME (DAY) METHODOLOGY REFERENCE RANGE
(UNIT) -
Irregular antibodies (antibody identification/antibody titer measurement)
Serum and blood (EDTA-2Na added)
5.0 and 2.0
S09
↓
A00 and PN2,PN5
と
3-5 Column aggregation method [Coombs method, enzyme method (ficin method)]Enzymatic method
This technique is based on the same assay principle as the colorimetry. Analytes are specifically measured using enzymatic reactions.
COMMENT
*) Please submit serum and blood (EDTA-2Na added) in pairs. Regarding serum, please separate the blood immediately after collecting it. Please submit a single specimen for each requested item. Please specify your age, blood transfusion history, and disease name.
*) Please submit the specimen (blood or serum) on the day of blood collection as it may affect the test results.
Please note that tests performed on samples taken more than 48 hours after blood collection may be reported as reference values.
[00346 7]Indirect COM test, [00347 6]Irregular antibodies, [00344 9]About blood type incompatible pregnancy
Antibodies detected by complement activation may be missed in plasma samples. Therefore, please submit your serum.
About blood specimens for tests that use blood cells
For tests that use blood cells, false positives or abnormal reactions may occur when containers containing coagulation promoters and separation agents are used. Please be sure to submit in the designated container (EDTA-2Na added).
Collect 2.0mL of blood into the container shown below, mix well, store at room temperature, and submit immediately. Also, collect 10.0 to 15.0 mL of blood into a separate container, immediately separate the serum, and store it in the refrigerator.
Please avoid duplicate requests with other items.
CONTAINER
S09 旧容器記号 C1 1 セ X1
分離剤入り (真空採血量9mL)
貯蔵方法:室温
有効期間:製造から1年
A00 旧容器記号 X
ポリスピッツ
貯蔵方法:室温
PN2 旧容器記号 C C3 4
EDTA-2Na入り (真空採血量2mL)
内容:EDTA-2Na 3.0mg
貯蔵方法:室温
有効期間:製造から2年
PN5 旧容器記号 C C3 4
EDTA-2Na入り (真空採血量5mL)
内容:EDTA-2Na 7.5mg
貯蔵方法:室温
有効期間:製造から2年
supplementary information
不規則性抗体について
※一部を除き、不規則性抗体が同定された場合に抗体価測定を実施します。
- 不規則性抗体検査は、カラム凝集法にて、クームス法・酵素法 (フィシン法) を実施しております。
これらの方法は37℃にて加温するため、低温反応性抗体 (冷式抗体および寒冷凝集素) は検出できない場合があります。 - 自己対照陽性時の解離同定試験は実施しておりません。
- 不規則性抗体スクリーニング時、自己対照は実施しておりません。